Designed for fast installation of the the heating cable, simply loop the floor heating cable around the guide as you lay the cable system across the subfloor.
Secure the cable guides according to the planned layout using screws, nails, adhesive or glue approved for use with the given subfloor. The heating element should be spaced 3" apart across the area to be heated. Cable guides should be run perpendicular to heating cables. The heating cables should have a minimum distance of 2" from walls and objects. Spacing between cable guides should not exceed 36" in distance. Secure the heating element to cable guides by wrapping the wire around the stud. Maintain moderate tension of cable throughout installation. Do not twist heating element and keep the minimum bending radius of the cable to 1".
Cable guides are 12" long and can be cut to length.
Includes enough cable guides for up to 25 sq. ft. cable system.